Browse categories

hard disk seagate barracuda 3tb

hard disk seagate barracuda 3tb
Asking price: €50
Make an offer:
Seller:
thejafo
Feedback:
25 0
Location:
7 more ads from this seller
Entered/Renewed:
11 months ago
Ad Views:
210
Viewing 1 of 1
hard disk seagate barracuda 3tb

Description

selling unused hdd seagate barracuda 3tb sata3 model st3000dm001 due to storage upgrade.

see picture for full details

smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.17.0-7-generic] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1CH166
Serial Number: Z1F4VLNK
LU WWN Device Id: 5 000c50 066350c35
Firmware Version: CC27
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Feb 28 12:49:33 2026 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 575) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 318) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 119 094 006 Pre-fail Always - 206980344
3 Spin_Up_Time 0x0003 094 093 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1383
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 085 060 030 Pre-fail Always - 396574446
9 Power_On_Hours 0x0032 021 021 000 Old_age Always - 69898
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 161
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 036 036 000 Old_age Always - 64
188 Command_Timeout 0x0032 100 098 000 Old_age Always - 1 4 22
189 High_Fly_Writes 0x003a 081 081 000 Old_age Always - 19
190 Airflow_Temperature_Cel 0x0022 076 043 045 Old_age Always In_the_past 24 (0 168 24 20 0)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 89
193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 616698
194 Temperature_Celsius 0x0022 024 057 000 Old_age Always - 24 (0 13 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 64659h+17m+09.213s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 149463492031
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1089507552370

SMART Error Log Version: 1
ATA Error Count: 64 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 64 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:37.182 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:33.446 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:29.697 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT

Error 63 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:33.446 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:29.697 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT

Error 62 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:29.697 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:14.779 READ DMA EXT

Error 61 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:14.779 READ DMA EXT
25 00 08 00 04 00 40 00 00:06:14.768 READ DMA EXT

Error 60 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:14.779 READ DMA EXT
25 00 08 00 04 00 40 00 00:06:14.768 READ DMA EXT
25 00 08 00 02 00 40 00 00:06:14.674 READ DMA EXT

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 23233 -
# 2 Extended offline Completed without error 00% 23218 -
# 3 Short offline Completed without error 00% 23185 -
# 4 Short offline Completed without error 00% 23161 -
# 5 Short offline Completed without error 00% 23137 -
# 6 Short offline Completed without error 00% 23113 -
# 7 Short offline Completed without error 00% 23089 -
# 8 Short offline Completed without error 00% 23065 -
# 9 Short offline Completed without error 00% 23041 -
#10 Extended offline Completed without error 00% 23041 -
#11 Short offline Completed without error 00% 23017 -
#12 Short offline Completed without error 00% 22993 -
#13 Short offline Completed without error 00% 22969 -
#14 Short offline Completed without error 00% 22945 -
#15 Short offline Completed without error 00% 22921 -
#16 Short offline Completed without error 00% 22897 -
#17 Short offline Completed without error 00% 22873 -
#18 Extended offline Completed without error 00% 22873 -
#19 Short offline Completed without error 00% 22849 -
#20 Short offline Completed without error 00% 22825 -
#21 Short offline Completed without error 00% 22801 -

Shipping: Collection
Payment: CashPaypalTo be arranged
From sellers around the web:
Comments & Offers
blingblingboy 4 months ago
€30 OFFERED
thejafo 4 months ago
@blingblingboy no thanks

See more in our Hard Drives category available today

€10.00
€15.00
€9.00
€275.00
€25.00
€30.00
€45.00
€8.00
€15.00
€10.00